Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Journal of Blood Transfusion ; (12): 371-376, 2021.
Article in Chinese | WPRIM | ID: wpr-1004526

ABSTRACT

【Objective】 To investigate the unqualified rate of anti-HIV detection of blood screening laboratories in Beijing-Tianjin-Hebei region, and explore the differences in anti-HIV detection ability and influencing factors in each laboratory. 【Methods】 Through filling questionnaires via e-mail, the anti-HIV ELISA unqualified rate and confirmed (WB) positive results (data) from January to December 2018 from 15 blood screening laboratories in Beijing-Tianjin-Hebei region were collected. Our laboratory was responsible for data collection and confirmation, and statistics software SPSS22.0 was used for analysis. 【Results】 1) There was a statistically significant difference among the unqualified rate of anti-HIV ELISA(6.77‱~35.71‱) and confirmed positive rate(0.60‱~3.56‱) in 15 blood screening laboratories in Beijing-Tianjin-Hebei region (P<0.05); 2) There were significant differencse among the ELISA unqualified rate and the confirmed positive rate of 8 reagents for anti-HIV detection(P<0.01), and the sensitivity of the 4th generation detection reagent and the imported reagent was higher than that of the 3rd generation reagent and the domestic reagent. The anti-HIV ELISA unqualified rate of R5 was the highest (19.08‱). 3)There were significant differences in the anti-HIV ELISA unqualified rate of R1, R2, R3, R5 and R7 reagents among different blood station laboratories(P<0.05), and there were no significant differences in the anti-HIV ELISA unqualified rate of R4, R6 and R8 reagents among different blood station laboratories(P>0.05). 4)The unqualified rate of anti-HIV ELISA of laboratories using different regents showed significant differences(P<0.05), except H, J, M. The unqualified rate of imported reagent was significantly higher than that of domestic reagents of laboratories using imported and domestic reagents combinations(P<0.05), except O. 62.5% (5/8) laboratories using domestic 3rd and 4th generation reagent combination showed significant differences in the unqualified rates among different reagents(P<0.05); 5) The positive rate of single-reagent(62.02%~95.45%)in 15 blood screening laboratories showed significant difference(P<0.001), and A was the lowest (62.02%). 【Conclusion】 The anti-HIV detection ability among 15 blood screening laboratories in Beijing-Tianjin-Hebei region is quite different. The application of different reagents is the main factor for the difference, and other factors such as personnel, instruments and test strategies also has a great impact on the detection of anti-HIV. It is still necessary to promote the process of homogenization of blood testing quality among blood screening laboratories in Beijing-Tianjin-Hebei region.

SELECTION OF CITATIONS
SEARCH DETAIL